{"product_id":"ericson-1066fs-temporary-power-distribution-center-reconditioned","title":"Ericson 1066FS Temporary Power Distribution Center - Reconditioned","description":"\u003cdiv\u003e\n\u003ch2 style=\"font-size: 1.5em; font-weight: bold;\"\u003eEricson 1066FS Temporary Power Distribution Center - Reconditioned\u003c\/h2\u003e\n\u003cp style=\"margin-bottom: 10px;\"\u003eReconditioned Ericson 1066FS OSCAR temporary power distribution center rated at 50A, 125\/250V for use on construction and MRO jobsites. Features six GFCI-protected 5-20R duplex outlets and one L6-30 receptacle, all housed in a heavy-duty powder-coated steel NEMA 3R enclosure. CS6369 feed-through outlet allows daisy chaining to additional units. ETL listed to UL 1640.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 20px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 10px;\"\u003e\n\u003cli\u003e50A 125\/250V input via CS6375 inlet with CS6369 feed-through for daisy chaining\u003c\/li\u003e\n\u003cli\u003e6x NEMA 5-20R duplex outlets, each individually GFCI protected with open neutral protection\u003c\/li\u003e\n\u003cli\u003e1x L6-30 receptacle with overload protection (non-GFCI)\u003c\/li\u003e\n\u003cli\u003eManual power-up GFCIs require reset on plug-in to prevent accidental equipment start-up\u003c\/li\u003e\n\u003cli\u003eFlip covers protect outlets and circuit breakers from damage and weather\u003c\/li\u003e\n\u003cli\u003eAll steel construction, powder-coated inside and out to prevent corrosion\u003c\/li\u003e\n\u003cli\u003eHeavy-duty powder-coated steel skids for rugged jobsite performance\u003c\/li\u003e\n\u003cli\u003ePower inlet and outlet clearly marked on lid for quick identification\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNEMA 3R rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eMade in USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin-top: 20px;\"\u003eIncluded\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 10px;\"\u003e\n\u003cli\u003e1x Ericson 1066FS Temporary Power Distribution Center\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin-top: 20px;\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 10px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eModel\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1066FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eSKU\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1066FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eUPC\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e782862796115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eElectrical Rating\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e50A, 125\/250V, 6250W\/12500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003ePhase\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003ePower Inlet\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCS6375 (50A, 125\/250V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003ePower Outlet\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCS6369 (50A, 125\/250V) feed-through\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eReceptacles - A\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6x NEMA 5-20R (20A, 125V) - GFCI protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eReceptacles - B\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e1x L6-30 (30A, 250V) - non-GFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eEnvironmental Rating\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eNEMA 3R (outdoor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eConstruction\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePowder-coated steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eColor\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSafety Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eListings\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eETL listed to UL 1640, cETL listed to CSA C22.2 No.107.1, RoHS Compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eCountry of Origin\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eCondition\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eReconditioned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"margin-top: 20px;\"\u003eDimensions\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 10px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eLength\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e22.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eWidth\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e16.25 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eHeight\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e11.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e34 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Ericson","offers":[{"title":"Default Title","offer_id":48904713535731,"sku":"Ericson 1066FS","price":595.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0064\/7597\/2675\/files\/1066FS-1.jpg?v=1777913344","url":"https:\/\/www.gequip.com\/products\/ericson-1066fs-temporary-power-distribution-center-reconditioned","provider":"General Equipment \u0026 Supply","version":"1.0","type":"link"}